Design codes
8 min read· November 24, 2026

Eurocode 7 pile design: a step-by-step guide (EN 1997-1)

How to design a pile to Eurocode 7: design actions, characteristic resistance from load tests or calculation, Design Approaches, partial factors and a published check.


Eurocode 7 pile design comes down to one inequality: the design axial action must not exceed the design resistance, Fc;d ≤ Rc;d. The work is in the two sides. Actions are combined and factored by EN 1990. The resistance starts as a characteristic value Rc;k, obtained from load tests or from calculation, and is divided by the partial factors of a Design Approach. This guide walks through the five steps for a single pile in compression and tension to EN 1997-1:2004, with the recommended factor values and a published example.

The check in one line

compression:  Fc;d ≤ Rc;d      (EN 1997-1 7.6.2.1)
tension:      Ft;d ≤ Rt;d      (EN 1997-1 7.6.3.1)

Everything else in section 7.6 of EN 1997-1 is about how to get the four terms. A pile check to the Italian NTC 2018 has the same shape with its own factor tables.

Step 1: the design action

Take each axial action at its characteristic value and class it as permanent (G) or variable (Q). EN 1990 eq. 6.10 then gives the design value:

Fc;d = Σ γG · Gk  +  γQ · Qk,1  +  Σ γQ · ψ0,i · Qk,i

One variable action leads at its full value and the others accompany it at ψ0. Each variable action takes its turn as the leading one. The recommended partial factors on actions (EN 1997-1 Table A.3) come in two sets:

SetPermanent, unfavourablePermanent, favourableVariable, unfavourableVariable, favourable
A11.351.01.50
A21.01.01.30

EN 1990 also allows the pair of eqs 6.10a and 6.10b in place of 6.10. They apply to set A1 only, and 6.10b reduces the unfavourable permanent actions by ξ (0.85 recommended, 0.925 in the UK National Annex to EN 1990). Do not confuse this ξ with the correlation factors of step 2.

Two details are easy to miss. The pile's own weight is a permanent action in a calculation-based check (JRC EUR 26227 §8.4.2). And where the ground can settle relative to the pile, EN 1997-1 7.3.2.2 treats the drag load as an action at its maximum value, so it belongs on the action side too.

Step 2: the characteristic resistance

EN 1997-1 offers three routes to Rc;k.

  • Static load tests (7.6.2.2). Rc;k is the lesser of the mean measured resistance over ξ1 and the lowest over ξ2. Both factors fall as the number of tests grows.
  • Ground test results (7.6.2.3). A calculation method is run on each investigated profile (borehole or CPT). Rc;k is the lesser of the mean calculated resistance over ξ3 and the lowest over ξ4. This is often called the model pile procedure.
  • The alternative procedure (7.6.2.3(8)). The method runs once on characteristic ground parameters: Rb;k = Ab · qb;k and Rs;k = Σ As,i · qs,i;k. No ξ is applied. The note to the clause says the resistance factors may then need a model factor γRd above 1.0. The recommended values give none; the UK National Annex gives 1.4 (1.2 with load-test verification) and the Irish National Annex gives 1.75.

The ξ tables, with a worked case for each route, are in correlation factors ξ1 to ξ4 explained.

Step 3: the Design Approach

A Design Approach says which factor sets go together: A on actions, M on ground strengths and R on resistances. For piles:

Design ApproachCombinationWhere the margin sits
DA1, combination 1A1 + M1 + R1Actions
DA1, combination 2A2 + M1 + R4Resistance
DA2A1 + M1 + R2Actions and resistance
DA3A1 + M2 + R3Actions and ground strength

DA1 needs both of its combinations to pass. Your National Annex chooses the approach: the UK allows DA1 only, Ireland allows all three, and Italy's NTC 2018 uses its own Approccio 2 (A1+M1+R3). The factor values and the reasoning behind each approach are in Design Approaches 1, 2 and 3 for piles.

Step 4: the design resistance

from load tests:   Rc;d = Rc;k / γt
from calculation:  Rc;d = Rb;k / γb  +  Rs;k / γs
in tension:        Rt;d = Rt;k / γs;t

The base, shaft and total factors depend on how the pile is installed. The recommended values (EN 1997-1 Tables A.6 to A.8) for the two sets that matter most in DA1:

PileSetγb (base)γs (shaft)γt (total)γs;t (tension)
DrivenR11.01.01.01.25
DrivenR41.31.31.31.6
BoredR11.251.01.151.25
BoredR41.61.31.51.6
CFAR11.11.01.11.25
CFAR41.451.31.41.6

Under R2 every compression factor is 1.1 and the tension factor is 1.15, whatever the pile type. Under R3 the compression factors are 1.0 and the tension factor is 1.1. With the alternative procedure, each factor is multiplied by the model factor.

Step 5: tension, and what the check leaves out

A pile in tension has no base term. Rt;k comes from the shaft alone, with the same routes as compression, and is divided by γs;t. The pile's weight now helps, so it enters as a favourable permanent action at 1.0.

The ultimate limit state check above is not the whole design. It does not cover:

  • settlement and the serviceability limit state, which often govern the working load;
  • transverse loading and the structural design of the pile section;
  • group effects, including block failure of a pile group;
  • the quality of the calculation method itself, which the factors assume is sound.

A published example in five lines

Example A.8.1 of the JRC report Eurocode 7: Geotechnical Design. Worked examples (EUR 26227, 2013) designs a foundation on bored piles from four static load tests. The measured resistances are 2.14, 1.96, 1.73 and 2.33 MN. The foundation carries Gk = 6.0 MN and Qk = 3.2 MN.

mean = 2.04 MN, lowest = 1.73 MN, n = 4:  ξ1 = 1.1, ξ2 = 1.0
Rc;k = min(2.04 / 1.1 ; 1.73 / 1.0) = 1.73 MN per pile

DA1 comb. 1:  Fc;d = 1.35·6.0 + 1.5·3.2 = 12.9 MN   Rc;d = 1.73 / 1.15 = 1.50 MN
DA1 comb. 2:  Fc;d = 1.0·6.0 + 1.3·3.2 = 10.2 MN    Rc;d = 1.73 / 1.5  = 1.15 MN
DA2:          Fc;d = 12.9 MN                        Rc;d = 1.73 / 1.1  = 1.57 MN

All three need nine piles (12.9 / 1.50 = 8.6, 10.2 / 1.15 = 8.8, 12.9 / 1.57 = 8.2). A full calculation-based case, with pile lengths for every Design Approach, is in the Eurocode 7 pile design worked example.

How PileCalc runs the check

The axial pile, drilled-shaft and capacity-vs-length tools have a limit-state design switch. Turn it on and the factors of safety are replaced by a design basis: the code (EN 1997-1:2004, NTC 2018 or your own factors), the National Annex, the Design Approach, the combination rule, the installation type and the source of the characteristic resistance. You enter the actions at characteristic values. The tool's own method still computes the resistance: NAVFAC DM-7.02 for axial piles and FHWA-IF-99-025 for drilled shafts, or unit resistances you enter or derive from CPT.

The result lists Rc;k and how it was obtained, every partial and correlation factor with its table reference, and Ed, Rd and the utilisation for each combination. Where the codes leave a choice open, the app takes the conservative reading and says so in the response. The check covers axial compression and tension of single piles. Lateral, group and footing analyses do not have a design mode, and downdrag is not computed inside the check. The details are in the Eurocode 7 and NTC 2018 design docs and on the Eurocode 7 pile design page.

Common questions

How do you design a pile to Eurocode 7?

Show that the design axial action does not exceed the design resistance, Fc;d ≤ Rc;d. Combine the characteristic actions with the EN 1990 partial factors, derive a characteristic resistance Rc;k from static load tests, from calculations on ground test profiles or from characteristic ground parameters, then divide it by the resistance factors of the Design Approach your National Annex selects.

What is the characteristic resistance of a pile in Eurocode 7?

Rc;k is a cautious estimate of the pile's compressive resistance. From static load tests it is the lesser of the mean measured resistance divided by ξ1 and the lowest divided by ξ2. From ground test profiles it is the lesser of the mean calculated resistance divided by ξ3 and the lowest divided by ξ4. With the alternative procedure it is calculated from characteristic ground parameters and a model factor is applied to the resistance factors.

Is the pile's self-weight included in the design action?

Usually yes. JRC EUR 26227 §8.4.2 includes the pile self-weight in Fc;d unless the overburden balances it, and NTC 2018 §6.4.3 treats it as a permanent action. PileCalc adds the effective pile weight as a permanent action in calculation-based checks, and leaves it out when the resistance comes from load tests, because the measured head load already includes it.

Does Eurocode 7 use a factor of safety for piles?

Not a single one. The margin is split between partial factors on actions, correlation factors or a model factor on the resistance, and partial resistance factors. Multiplied together for a driven pile designed from one ground profile with the recommended values, they are equivalent to an overall factor of about 2.0 under Design Approach 1 and about 2.2 under Design Approach 2, for a permanent to variable load ratio of 2 to 1.

Which edition of Eurocode 7 does PileCalc check to?

EN 1997-1:2004, with the Annex A recommended values or the UK or Irish National Annex, and the Italian NTC 2018. The second-generation EN 1997-3:2025 is not offered, because its pile factors are not publicly reproduced. A custom basis takes every factor from you.

Sources

Factor values are quoted from the public reproductions of EN 1997-1:2004 Annex A in JRC EUR 26227 (Bond, Schuppener, Scarpelli and Orr, 2013), Tables 8.4.1 to 8.4.3, and of EN 1990 in the JRC EN 1990 workshop (Calgaro, 2008). Check the values against the standard and the National Annex that govern your project. The design remains the engineer's responsibility.

Keep reading

Design codes
November 24, 2026

Eurocode 7 pile design worked example (DA1, DA2, DA3)

A driven pile in stiff clay sized under all three Design Approaches, following JRC example A.8.2 step by step, with the same case run in PileCalc.

Read
Design codes
November 24, 2026

Eurocode 7 Design Approaches 1, 2 and 3 for piles

DA1, DA2 and DA3 for pile design: the A, M and R factor sets, the recommended resistance factors, which combination governs, and one pile sized under all three.

Read
Design codes
November 24, 2026

Eurocode 7 correlation factors ξ1 to ξ4 for pile resistance

Correlation factor tables for EN 1997-1, the UK and Irish National Annexes and NTC 2018, with worked examples of characteristic pile resistance from load tests.

Read

See it for yourself

Run a laterally loaded pile in your browser — with the deflected shape, moment diagram, and every input explained.

Launch the app