Eurocode 7 and NTC 2018 design

Check axial piles and drilled shafts to EN 1997-1 (DA1, DA2, DA3; UK and Irish National Annexes) or NTC 2018: correlation factors, model factor and actions.


The axial pile, drilled-shaft and capacity-vs-length tools can check a pile against a limit-state design basis (EN 1997-1:2004 Eurocode 7 or the Italian NTC 2018), as well as the allowable-stress factors of safety. The engine still computes the resistance with the tool's method. Design mode then turns it into a characteristic and a design resistance, builds the design effect from your actions, and reports Ed/Rd for every combination.

What design mode does

With a design basis, the factors of safety (fsTip, fsSide, …) are omitted. The response then carries a design check with these parts:

  • the characteristic resistance Rc,k (and Rt,k in tension), and how it was obtained;
  • the partial factors and correlation factors that were applied, with their table references;
  • the design effect Ed and the design resistance Rd per combination, and the governing utilisation;
  • a designBasis stamp that the PDF report repeats, so the factors used stay traceable.

Factor values come only from public reproductions of the standards. The sources and the double transcription of every table are recorded in the repository's Eurocode research record, and the published worked examples reproduced (for example Orr, 2005, Example 3, and JRC EUR 26227 A.8.1) are listed on the validation page.

Codes and National Annexes

  • NTC 2018: Approccio 2 (A1+M1+R3) for piles, Tab. 6.4.II, with ξ3/ξ4 from Tab. 6.4.IV. The seismic situation uses unit partial factors and ψ2.
  • EN 1997-1 recommended values: Annex A factors with DA1, DA2 or DA3.
  • UK National Annex: DA1 only, with the A.NA R4 factors (lower set when serviceability is verified) and the UK model factor. ψ and the eq. 6.10b factor ξ = 0.925 come from the UK National Annex to EN 1990 (Table NA.A1.1: roofs ψ0 = 0.7, wind ψ0 = 0.5).
  • Irish National Annex: calculation from ground tests with the published ξ3/ξ4 and model factor. Load-test factors for Ireland are not publicly reproduced, so that source is not offered. ψ comes from the Irish National Annex to EN 1990 (roofs ψ0 = 0.6). Only the categories that two public reproductions agree on are offered; give ψ0 directly for any other. ξ in eq. 6.10b is the recommended 0.85, which only one public reproduction confirms, and the response says so.
  • Custom: every factor is entered by you.

Design approaches

DA1 checks two combinations: 1 (A1+M1+R1) and 2 (A2+M1+R4). DA2 is A1+M1+R2. DA3 is A1+M2+R3. Because R3 is 1.0 in compression, DA3 is accepted only with the characteristic-parameter source. JRC EUR 26227 §8.5 advises against it for piles designed from load tests or from profiles of test results, so the app offers it only there.

Under M2 the method runs on design strengths, cu/1.4 and qu/1.4. The NAVFAC adhesion ratio, the FHWA drilled-shaft α and the rock-socket law 0.65·√(pa·qu) all depend on strength, so the app reads them at the characteristic strength. The shaft resistance then falls by the full 1.4, as in JRC EUR 26227 example A.8.2.3, where α is held constant. Reading them at the reduced strength would cancel most of the factor.

Actions and combinations

Enter each axial action at its characteristic value: compression positive, tension negative. Classify it as permanent (G), variable (Q) or, under NTC 2018 seismic, seismic (E). A variable action can take ψ from an action category (EN 1990 Table A1.1, or Table NA.A1.1 of the selected UK or Irish National Annex; NTC 2018 Tab. 2.5.I) or from ψ0/ψ2 that you enter. Under EN 1990 you choose eq. 6.10 or the pair 6.10a/6.10b. The pair applies to set A1 only (EN 1990 Table A1.2(B)), so DA1 combination 2 (A2) always uses eq. 6.10, and eq. 6.10a needs ψ0 for every variable action. Pile self-weight is added as a permanent action in calculation-based checks. It is not added for load-test resistance, because the measured head load already includes it. The self-weight also counts when the checks are chosen, so a pile under uplift alone is checked in compression too.

Where the characteristic resistance comes from

  • Static load tests: Rc,k is the lesser of the mean measured resistance over ξ1 and the minimum over ξ2 (EN 1997-1 7.6.2.2, NTC 2018 §6.4.3.1.1).
  • Ground test profiles: the tool's method runs on each investigated vertical. Rc,k is the lesser of the mean over ξ3 and the weakest over ξ4 (EN 1997-1 7.6.2.3).
  • Characteristic parameters (EN 1997-1 only): the alternative procedure. The method runs once on characteristic soil values and the partial factors are increased by the model factor.

Investigated verticals

A vertical is one borehole, CPT or other investigated profile. Add further verticals under the tool's soil profile, or link project soil profiles. The correlation factors depend on the number of verticals n, and both ξ3 and ξ4 fall as n grows. For an n between the printed counts, the next lower printed count is used. The codes give only the total resistance, so the base/shaft split over verticals keeps both branches (mean and weakest) and uses the smaller design resistance.

Model factor

With the characteristic-parameter source, EN 1997-1 7.6.2.3(8) notes that the resistance factors may need to be corrected by a model factor γRd, and 7.6.3.3(6) says the same for tension. The recommended values give none, so you enter the project value and the response warns that it was applied. The UK and Irish National Annexes publish their own values, and the app uses those. The Irish factor is also applied to γs,t.

Entered and CPT unit resistances

An axial soil layer can carry its own characteristic unit resistances, replacing the NAVFAC DM-7.02 values in that layer:

  • Unit shaft resistance qs: used in compression and uplift. Enter 0 to exclude the layer.
  • Unit base resistance qb: used when the pile tip bears in the layer.
  • CPT cone resistance qc (bored piles in sand): qs from EN 1997-2 Table D.4 and qb from Table D.3 at s/D = 0.10, as reproduced in JRC EUR 26227 (2013). qc at the tip must be 10–25 MPa, the table's range. The tables' other conditions of application are not checked.

A weak layer below the tip

When a weaker layer starts within 10 pile diameters below the tip, the tip resistance is limited for punching into it (FHWA-IF-99-025 Eq. B.68b). If that lower layer carries an entered or in-range CPT base resistance, the check uses the lower of that value and the layer's NAVFAC value. The source defines the lower-layer value only from the layer's own capacity, and a cautious estimate (EN 1997-1 §2.4.5.2) should not be raised by an entered number. The response warns when the entered value governs.

The values you enter are yours. The response notes every layer whose resistance did not come from NAVFAC.

Custom factors

The custom basis takes one card per combination, with its partial factors on actions, materials and resistances. It also takes the ξ pair for your resistance source. Nothing is filled in for you, and a missing factor is reported as required. Record the source of your factors with the design.

Conventions and limits

  • Only factors available from public reproductions are offered. EN 1997-3:2025 is not offered, because its pile factors are not publicly reproduced.
  • Where the codes are silent (the base/shaft split over verticals, untabulated n, the sign convention for favourable permanent actions, reversible seismic effects), the app takes the conservative reading and says so in the response.
  • The stiff-structure option divides ξ by 1.1 (not below 1.0) in the compression check only. EN 1997-1 allows it in 7.6.2.2(9) and 7.6.2.3(7); the tension clauses 7.6.3.2 and 7.6.3.3 have no such allowance.
  • Downdrag is not computed in design mode. Where the ground can settle relative to the pile, EN 1997-1 7.3.2.2 treats the drag load as an action at its maximum value: work it out with the downdrag analysis and enter it as a permanent action. Every compression check says so.
  • Design mode changes how resistance is factored, not the resistance method. The limits of the tool's method still apply; see axial capacity and drilled shafts.