Eurocode 7 and NTC 2018 pile design checks, in your browser.
Check axial piles and drilled shafts to EN 1997-1 (DA1, DA2 or DA3, with the recommended values or the UK or Irish National Annex) or to the Italian NTC 2018. Every partial factor, correlation factor and table reference is in the result.
Design mode adds a limit-state check to the axial pile, drilled-shaft and capacity-vs-length tools. The tool's own method still computes the resistance: NAVFAC DM-7.02 for axial piles and FHWA-IF-99-025 for drilled shafts. In the axial pile and capacity-vs-length tools, a layer can instead carry unit resistances you enter or derive from CPT cone resistance (EN 1997-2 Annex D, bored piles in sand). Design mode turns that into a characteristic resistance Rc,k (and Rt,k in tension) and a design resistance Rd. It builds the design effect Ed from your characteristic actions and reports Ed/Rd for every combination, with the governing utilisation.
Under EN 1997-1:2004 you choose Design Approach 1 (combinations A1+M1+R1 and A2+M1+R4), Design Approach 2 (A1+M1+R2) or Design Approach 3 (A1+M2+R3). The factors are the Annex A recommended values or a UK or Irish National Annex preset, and actions combine by EN 1990 eq. 6.10 or the 6.10a/6.10b pair. Under NTC 2018 the check uses Approccio 2 (A1+M1+R3) for piles, with ξ3/ξ4 from Tab. 6.4.IV and a seismic situation. A custom basis takes every factor from you.
The characteristic resistance comes from static load tests (ξ1/ξ2), from the method run on each investigated vertical (ξ3/ξ4 by the number of verticals), or, under EN 1997-1, from characteristic parameters with a model factor. Where the codes leave a choice open, the app takes the conservative reading and says so in the response.
Scope, plainly: design mode covers axial compression and tension of single piles and drilled shafts. Lateral, pile-group and footing analyses don't have it. EN 1997-3:2025 isn't offered, because its pile factors are not publicly reproduced. Downdrag isn't computed inside the check; work out the drag load with the downdrag analysis and enter it as a permanent action, as EN 1997-1 7.3.2.2 does.
DA1, DA2 and DA3
Partial factor sets A, M and R from EN 1997-1 Annex A. DA3 is offered with the characteristic-parameter source only, as JRC EUR 26227 §8.5 advises for piles.
UK and Irish National Annexes
UK: DA1 for axially loaded piles, with the R4 factors, the UK model factor, and ψ and ξ = 0.925 from the UK National Annex to EN 1990. Irish: piles designed by calculation, with the published ξ3/ξ4 and model factor.
NTC 2018
Approccio 2 (A1+M1+R3) from Tab. 6.4.II, ξ3/ξ4 from Tab. 6.4.IV, ψ from Tab. 2.5.I, and the seismic situation with unit partial factors and ψ2.
Correlation over investigated verticals
Add a borehole or CPT profile per vertical. Rc,k is the lesser of the mean over ξ3 and the weakest over ξ4, and the weakest vertical is named in the result.
Required length to EN 1997-1
In capacity vs length, the sweep reports the shortest swept length that passes every combination.
Traceable output
Factors with their table references, Ed and Rd per combination, and a design-basis stamp that the PDF report repeats. The same check runs through the REST API.
The numbers, published
PileCalc's engine is checked term-by-term against the reference codes. A representative sample of the benchmarks — every intermediate value is visible in the app so you can reproduce them yourself.
Eurocode 7 pile design: common questions
Go deeper
Run it on your next project
Try Pro free for 7 days — no install, no dongle, every input explained and every result visible.
Launch the app