Design codes
6 min read· November 24, 2026

NTC 2018 pile design: Approccio 2 (A1+M1+R3) and ξ factors

Pile verification to NTC 2018: A1+M1+R3, the R3 factors of Tab. 6.4.II, ξ3 and ξ4 of Tab. 6.4.IV, the seismic combination and a worked bored-pile example.


Under the Italian NTC 2018 (D.M. 17 gennaio 2018), the ultimate limit state check of an axially loaded pile uses one combination: Approccio 2, A1+M1+R3. Actions are factored by Tab. 6.2.I, the calculated resistance of each investigated vertical is reduced by the correlation factors ξ3 and ξ4 of Tab. 6.4.IV, and the result is divided by the R3 factors of Tab. 6.4.II. This page sets out the factors, the seismic combination, and a published worked example for a bored pile (palo trivellato).

The check

Ed ≤ Rd                                   NTC 2018 eq. [6.2.1]

Ed = γG1·G1 + γG2·G2 + γQ·Qk1 + Σ γQ·ψ0i·Qki        eq. [2.5.1]
Rc,k = min( mean(Rc,cal) / ξ3 ; min(Rc,cal) / ξ4 )   eqs [6.4.3], [6.4.4]
Rc,d = Rb,k / γb + Rs,k / γs

Actions: Tab. 6.2.I, set A1

ActionUnfavourableFavourable
Permanent, structural G11.31.0
Permanent, non-structural G21.50.8
Variable Q1.50

The split of permanent actions into G1 and G2 is the first difference from EN 1997-1, which has one permanent class at 1.35. The pile's own weight is a G1 action (§6.4.3). Accompanying variable actions take ψ0 from Tab. 2.5.I: 0.7 for residential, office, crowd and shopping areas, 1.0 for storage and industrial use, 0.6 for wind, and 0.5 for snow up to 1000 m.

Resistance: Tab. 6.4.II, set R3

ResistanceDriven (infissi)Bored (trivellati)CFA (ad elica continua)
Base γb1.151.351.30
Shaft in compression γs1.151.151.15
Total γt1.151.301.25
Shaft in tension γs,t1.251.251.25

The total factor γt applies when the characteristic resistance comes from static load tests, where base and shaft are not separated.

Correlation factors: Tab. 6.4.IV

Investigated verticals n123457≥ 10
ξ3 (on the mean)1.701.651.601.551.501.451.40
ξ4 (on the minimum)1.701.551.481.421.341.281.21

A vertical (verticale indagata) is one borehole, CPT or other investigated profile. The table prints no value for 6, 8 or 9 verticals. PileCalc then uses the next lower printed count, which is the conservative side because ξ falls as n grows, and says so in the result. For static load tests, Tab. 6.4.III gives ξ1 and ξ2 with the same values as EN 1997-1. All four are compared across codes in correlation factors ξ1 to ξ4 explained.

Worked example: bored pile, one vertical

This example is from the 2019 NTC 2018 course of the Ordine dei Geologi del Lazio. A bored pile has a calculated base resistance of 1372 kN and a calculated shaft resistance of 253 kN from a single investigated vertical. It carries G1 = 300 kN and Q = 150 kN, and its buoyant weight is W′ = 44 kN.

one vertical:  ξ3 = ξ4 = 1.70
Rb,k = 1372 / 1.70 = 807 kN
Rs,k =  253 / 1.70 = 149 kN

bored pile, R3:  γb = 1.35,  γs = 1.15
Rd = 807 / 1.35 + 149 / 1.15 = 598 + 130 = 728 kN

Ed = 1.3 · (300 + 44) + 1.5 · 150 = 672 kN

Ed / Rd = 672 / 728 = 0.92   →  verified

Note the weight: W′ is added to G1 and takes the 1.3 factor. Leaving it out would give Ed = 615 kN and overstate the margin. PileCalc's reference checks reproduce each printed value of this example.

The overall factor is worth seeing. Total calculated resistance is 1625 kN and the unfactored load including the weight is 494 kN, so a traditional global factor of safety would be 3.3. The limit-state check passes at 92 percent utilisation because, for a base-dominated bored pile on one vertical, the chain 1.36 (actions) × 1.70 (ξ) × 1.35 (base) is already close to 3.1. A second and third vertical would lower ξ3 to 1.65 and 1.60.

The seismic combination

For the seismic design situation NTC 2018 uses the combination of eq. [2.5.5]:

Ed = E + G1 + G2 + Σ ψ2i · Qki

§7.11.1 sets the partial factors on actions and on geotechnical parameters to 1. The resistance keeps the R3 factors and the ξ factors. Variable actions enter at ψ2: 0.3 for residential and office areas, 0.6 for crowd and shopping areas, 0.8 for storage, and 0 for wind and for snow up to 1000 m.

The code does not say which sign a seismic axial force takes in a single check. PileCalc treats E as reversible and applies it in the unfavourable sense of each check, compression and tension, and reports that convention in the result.

What NTC 2018 does not have

  • No choice of approach for piles. EN 1997-1 offers three Design Approaches. NTC 2018 fixes A1+M1+R3.
  • No stiff-structure reduction. EN 1997-1 lets ξ be divided by 1.1 for a structure that can redistribute load between piles. NTC 2018 §6.4.3 has no such rule.
  • No model-factor alternative. The characteristic resistance comes from load tests or from calculations on the investigated verticals with ξ3 and ξ4.

NTC 2018 checks in PileCalc

In the axial pile, drilled-shaft and capacity-vs-length tools, switch on limit-state design and choose NTC 2018 (Italy). Pick the installation type, the persistent or seismic situation and the source of the characteristic resistance, then enter each action as G1, G2, Q or E with its ψ category from Tab. 2.5.I. Add a soil profile for each investigated vertical. The result gives Rc,k, the ξ column used, Ed, Rd and the utilisation in compression and in tension, with the table and page of every factor.

The scope is the axial resistance of single piles. Transverse loading, pile groups and the structural verification of the pile are separate checks, and downdrag is not computed inside the design check. The general procedure is in the Eurocode 7 pile design guide, and the conventions PileCalc adopts where the code is silent are in the design mode docs.

Common questions

Which design approach does NTC 2018 use for piles?

Approccio 2, with the single combination A1+M1+R3 (NTC 2018 §6.4.3.1). Actions take the A1 factors of Tab. 6.2.I, ground parameters are unfactored (M1), and the resistance takes the R3 factors of Tab. 6.4.II, which depend on whether the pile is driven, bored or continuous flight auger.

What are the NTC 2018 resistance factors for piles?

From Tab. 6.4.II, set R3: driven piles (pali infissi) γb = 1.15, γs = 1.15, γt = 1.15; bored piles (pali trivellati) γb = 1.35, γs = 1.15, γt = 1.30; continuous flight auger piles (pali ad elica continua) γb = 1.30, γs = 1.15, γt = 1.25. The shaft factor in tension γs,t is 1.25 for all three.

What are ξ3 and ξ4 in NTC 2018?

They are the correlation factors of Tab. 6.4.IV that turn resistances calculated on the investigated verticals into a characteristic resistance. ξ3 divides the mean and ξ4 the minimum. ξ3 is 1.70, 1.65, 1.60, 1.55, 1.50, 1.45 and 1.40 for 1, 2, 3, 4, 5, 7 and 10 or more verticals. ξ4 is 1.70, 1.55, 1.48, 1.42, 1.34, 1.28 and 1.21.

How is a pile checked in the seismic combination under NTC 2018?

The seismic combination of eq. [2.5.5] is E + G1 + G2 + Σ ψ2·Qk. NTC 2018 §7.11.1 sets the partial factors on actions and on geotechnical parameters to 1, and the resistance is still divided by the R3 factors. Variable actions enter at their quasi-permanent value through ψ2 of Tab. 2.5.I.

Is the pile's weight included in the NTC 2018 check?

Yes. NTC 2018 §6.4.3 treats the pile self-weight as a permanent action. PileCalc adds the effective (buoyant) pile weight as a G1 action in calculation-based checks: unfavourable at 1.3 in compression and favourable at 1.0 in tension.

How does NTC 2018 differ from Eurocode 7 for pile design?

The structure is the same, with different numbers and fewer options. NTC 2018 has one approach for piles (A1+M1+R3), splits permanent actions into G1 (1.3) and G2 (1.5), uses higher correlation factors (1.70 against 1.40 for one profile), has no reduction of ξ for stiff structures and no model-factor alternative procedure.

Sources

D.M. 17 gennaio 2018, Aggiornamento delle Norme tecniche per le costruzioni (Gazzetta Ufficiale n. 42 del 20/02/2018, S.O. n. 8): §2.5.3, Tab. 2.5.I, Tab. 6.2.I, §6.4.3, Tab. 6.4.II to 6.4.IV and §7.11.1; Ordine dei Geologi del Lazio (2019), NTC 2018 course slides for the worked example. Check every value against the official text. The design remains the engineer's responsibility.

Keep reading

Design codes
November 24, 2026

Eurocode 7 pile design: a step-by-step guide (EN 1997-1)

How to design a pile to Eurocode 7: design actions, characteristic resistance from load tests or calculation, Design Approaches, partial factors and a published check.

Read
Design codes
November 24, 2026

Eurocode 7 pile design worked example (DA1, DA2, DA3)

A driven pile in stiff clay sized under all three Design Approaches, following JRC example A.8.2 step by step, with the same case run in PileCalc.

Read
Design codes
November 24, 2026

Eurocode 7 Design Approaches 1, 2 and 3 for piles

DA1, DA2 and DA3 for pile design: the A, M and R factor sets, the recommended resistance factors, which combination governs, and one pile sized under all three.

Read

See it for yourself

Run a laterally loaded pile in your browser — with the deflected shape, moment diagram, and every input explained.

Launch the app