Design codes
6 min read· November 24, 2026

Pile design to the UK National Annex to Eurocode 7

UK pile design to EC7: Design Approach 1, the R4 factors with and without serviceability verification, the 1.4 and 1.2 model factors, ξ values and a worked example.


Pile design to the UK National Annex to Eurocode 7 uses Design Approach 1 with national resistance factors and a model factor. The R1 factors are all 1.0, so the margin on resistance sits in the R4 set of combination 2, which has two columns: higher values by default and lower ones when the serviceability limit state is explicitly verified. When the resistance is calculated from ground parameters, a model factor of 1.4 is applied as well, or 1.2 with load-test verification. This page lists the values and works a short example.

Design Approach 1, two combinations

CombinationPermanent γGVariable γQGround strengthResistance
1 (A1+M1+R1)1.351.51.0R1 = 1.0
2 (A2+M1+R4)1.01.31.0R4, see below

The action factors are the recommended ones. Favourable permanent actions take 1.0 and favourable variable actions are left out. The UK is one of the countries that allows only DA1; the other approaches are described in Design Approaches 1, 2 and 3 for piles.

R4 resistance factors

Pile typeServiceabilityBase γbShaft γsTotal γtTension γs;t
DrivenNot explicitly verified1.71.51.72.0
DrivenVerified1.51.31.51.7
Bored and CFANot explicitly verified2.01.62.02.0
Bored and CFAVerified1.71.41.71.7

These are the values of Tables A.NA.6 to A.NA.8 as reproduced by Raison and Egan (2016) in the UK national report to the ISSMGE ETC3 symposium. The annex itself states the conditions under which serviceability counts as verified. Read them there before using the lower column.

The model factor

Most UK pile design calculates the resistance from characteristic ground parameters: an α method on a cautious estimate of cu, for instance. EN 1997-1 7.6.2.3(8) calls this the alternative procedure and notes that the resistance factors may need a model factor. The UK National Annex sets it:

  • γRd = 1.4 in general;
  • γRd = 1.2 when the calculated resistance is verified by static load testing.
Rc;d = Rb;k / (γb · γRd)  +  Rs;k / (γs · γRd)

The model factor applies in both combinations. It does not apply when the characteristic resistance comes from static load tests or from ground test profiles, where the correlation factors do the same job.

Correlation factors

n123457≥ 10
ξ1 (load tests, mean)1.551.471.421.381.351.351.35
ξ2 (load tests, minimum)1.551.351.231.151.081.081.08
ξ3 (profiles, mean)1.551.471.421.381.361.331.30
ξ4 (profiles, minimum)1.551.391.331.291.261.201.15

ξ1 and ξ2 are tabulated up to five tests, and the five-test value holds beyond that. For a structure stiff enough to redistribute load between piles, ξ may be divided by 1.1 in compression, but not below 1.0. How the factors are used is covered in correlation factors ξ1 to ξ4 explained.

Worked example: what verification is worth

Take a bored pile whose characteristic resistances, calculated from characteristic ground parameters, are Rb;k = 800 kN and Rs;k = 1600 kN. The characteristic actions, including the pile's weight, are Gk = 900 kN and Qk = 300 kN. The numbers are illustrative.

Combination 1:  Ed = 1.35·900 + 1.5·300 = 1665 kN
                Rd = (800 + 1600) / (1.0 · 1.4) = 1714 kN        Ed/Rd = 0.97

Combination 2:  Ed = 1.0·900 + 1.3·300 = 1290 kN

  no SLS verification, γRd = 1.4:
    Rd = 800/(2.0·1.4) + 1600/(1.6·1.4) = 286 + 714 = 1000 kN   Ed/Rd = 1.29

  SLS verified, γRd = 1.4:
    Rd = 800/(1.7·1.4) + 1600/(1.4·1.4) = 336 + 816 = 1152 kN   Ed/Rd = 1.12

  SLS verified, load-test verification, γRd = 1.2:
    Rd = 800/(1.7·1.2) + 1600/(1.4·1.2) = 392 + 952 = 1344 kN   Ed/Rd = 0.96

The same pile fails by 29 percent, fails by 12 percent, or passes, depending on what is verified. Combination 2 governs every case here. Going from the default column to full verification raises the design resistance by a third, which is the code's way of paying for load testing.

Actions to the UK National Annex to EN 1990

Two details differ from the recommended values and change the design action:

  • ψ0 for roofs is 0.7 and for wind is 0.5 (Table NA.A1.1), where EN 1990 Table A1.1 recommends 0 and 0.6. An accompanying roof load is therefore not dropped.
  • ξ = 0.925 in eq. 6.10b, where the recommended value is 0.85. The 6.10a and 6.10b pair applies to set A1 only, so combination 2 always uses eq. 6.10.

The UK preset in PileCalc

In the axial pile, drilled-shaft and capacity-vs-length tools, limit-state design offers UK National Annex (DA1). It fixes the approach to DA1 and loads the factors above. Two switches select the R4 column (serviceability verified or not) and the model factor (load-test verification or not). The resistance still comes from the tool's own method on your ground model, or from the load tests you enter. The result shows both combinations with every factor and the reference it was taken from.

Scope and caveats: the preset covers axially loaded single piles, in compression and tension. The National Annex is sold by BSI, so PileCalc's values come from public reproductions, each cross-checked between at least two sources. Check them against your copy of the annex. Settlement, lateral loading and group effects are separate checks. See the Eurocode 7 pile design guide for the full procedure and the design mode docs for the conventions.

Common questions

Which Design Approach does the UK National Annex use for piles?

Design Approach 1 only. Two combinations are checked: combination 1 (A1+M1+R1), where the R1 resistance factors are all 1.0, and combination 2 (A2+M1+R4), where the R4 factors carry the margin on resistance.

What is the UK model factor for pile design?

1.4, applied to the resistance factors when the characteristic resistance is calculated from characteristic ground parameters. It may be reduced to 1.2 when the calculated resistance is verified by static load testing. No model factor is used when the resistance comes from static load tests with ξ1 and ξ2, or from ground test profiles with ξ3 and ξ4.

What are the UK National Annex R4 factors for bored piles?

Without explicit verification of the serviceability limit state: base 2.0, shaft 1.6, total 2.0 and shaft in tension 2.0. With it: base 1.7, shaft 1.4, total 1.7 and shaft in tension 1.7. Continuous flight auger piles take the same values. Driven piles take 1.7, 1.5, 1.7 and 2.0 without verification, and 1.5, 1.3, 1.5 and 1.7 with it.

Does combination 1 or combination 2 govern in the UK?

Combination 2 in most cases, since R1 is 1.0 and R4 is between 1.3 and 2.0. Combination 1 can still govern a pile with mostly permanent load and a low R4 factor: for a driven pile with serviceability verified, a shaft factor of 1.3 against a permanent action factor of 1.35 leaves combination 1 slightly ahead. Both are always checked.

What ψ and ξ values does the UK National Annex to EN 1990 give?

Table NA.A1.1 follows the recommended ψ values except for roofs (ψ0 = 0.7, not 0) and wind (ψ0 = 0.5, not 0.6). For eq. 6.10b, the reduction factor on unfavourable permanent actions is ξ = 0.925 instead of the recommended 0.85.

Sources

Raison and Egan (2016), Design of piles: United Kingdom practice, ISSMGE ETC3 International Symposium on Design of Piles in Europe, Tables 1 to 7; Tang et al. (2022), 20th ICSMGE, paper 605; NA to BS EN 1990:2002+A1:2005, Table NA.A1.1 and NA.2.2.3.2. This page is not a substitute for the National Annex.

Keep reading

Design codes
November 24, 2026

Eurocode 7 pile design: a step-by-step guide (EN 1997-1)

How to design a pile to Eurocode 7: design actions, characteristic resistance from load tests or calculation, Design Approaches, partial factors and a published check.

Read
Design codes
November 24, 2026

Eurocode 7 pile design worked example (DA1, DA2, DA3)

A driven pile in stiff clay sized under all three Design Approaches, following JRC example A.8.2 step by step, with the same case run in PileCalc.

Read
Design codes
November 24, 2026

Eurocode 7 Design Approaches 1, 2 and 3 for piles

DA1, DA2 and DA3 for pile design: the A, M and R factor sets, the recommended resistance factors, which combination governs, and one pile sized under all three.

Read

See it for yourself

Run a laterally loaded pile in your browser — with the deflected shape, moment diagram, and every input explained.

Launch the app