Eurocode 7 partial factors vs a factor of safety for piles
What Eurocode 7 partial factors amount to as a global factor of safety: equivalent overall factors for DA1, DA2, the UK and Irish annexes and NTC 2018.
Engineers who learned pile design with a factor of safety of 2 to 3 often ask what Eurocode 7's partial factors amount to. The honest answer is a range, roughly 1.4 to 3, because the code moves the margin according to what you know: how the pile is installed, how the resistance was obtained, and how much of the load is variable. This page shows the conversion, with a table of equivalent overall factors for the common cases.
Two ways to write the same check
allowable stress: G + Q ≤ R_ult / FS
limit state: γG·G + γQ·Q ≤ R / (ξ · γR) ξ from tests or profiles
γG·G + γQ·Q ≤ R / (γR · γRd) alternative procedureIn the first, one number carries everything. In the second, the same margin is spread over the actions (γG, γQ), the reliability of the resistance estimate (a correlation factor ξ or a model factor γRd) and the resistance itself (γR, split into base and shaft). North American LRFD has the same structure, with a resistance factor φ below 1 in place of 1 / γR.
The equivalent overall factor
Rearranging the limit-state check into the allowable-stress form gives:
FS_equivalent = (γG·G + γQ·Q) / (G + Q) × γR × ξ (or γRd)The first term is the load-weighted action factor. For a permanent to variable ratio of 2 to 1 it is (1.35 · 2 + 1.5) / 3 = 1.40 with set A1 and (1.0 · 2 + 1.3) / 3 = 1.10 with set A2.
Equivalent factors for a driven pile
Driven piles have equal base and shaft factors in every recommended set, so the result does not depend on how the resistance is split. G : Q = 2 : 1 throughout.
| Basis | Resistance from | DA1 (governing) | DA2 |
|---|---|---|---|
| EN 1997-1 recommended | 1 ground profile (ξ = 1.40) | 2.00 | 2.16 |
| EN 1997-1 recommended | 10 profiles, uniform ground (ξ3 = 1.25) | 1.79 | 1.93 |
| EN 1997-1 recommended | 5 static load tests, uniform (ξ1 = 1.00) | 1.43 | 1.54 |
| Irish National Annex | characteristic parameters (γRd = 1.75) | 2.50 | 2.70 |
In each DA1 cell combination 2 governs: for example 1.10 × 1.3 × 1.40 = 2.00 against 1.40 × 1.0 × 1.40 = 1.96 for combination 1. The rows for several profiles or tests assume the mean branch governs. On variable ground the weakest result governs instead and the effective margin on the mean is larger.
National values
| Basis | Case | Shaft-only pile | Base-only pile |
|---|---|---|---|
| UK National Annex, driven, γRd = 1.4 | serviceability not explicitly verified | 2.31 | 2.62 |
| UK National Annex, driven, γRd = 1.2 | serviceability and load-test verification | 1.72 | 1.98 |
| UK National Annex, bored, γRd = 1.4 | serviceability not explicitly verified | 2.46 | 3.08 |
| UK National Annex, bored, γRd = 1.2 | serviceability and load-test verification | 1.85 | 2.24 |
| NTC 2018, driven | 1 investigated vertical (ξ = 1.70) | 2.67 | 2.67 |
| NTC 2018, driven | 10 verticals, uniform ground (ξ3 = 1.40) | 2.20 | 2.20 |
| NTC 2018, bored | 1 investigated vertical (ξ = 1.70) | 2.67 | 3.14 |
The UK rows use the model-factor route and combination 2 of DA1. The NTC 2018 rows treat all permanent load as G1, so the action factor is (1.3 · 2 + 1.5) / 3 = 1.37. A real pile lies between the shaft-only and base-only columns in proportion to its resistance split. These are products of the tabulated factors, for comparison only. They are not design values.
What the single number hides
- Load mix. Variable load is factored more than permanent load. A pile carrying mostly variable load has a higher equivalent factor than one carrying mostly dead load.
- Knowledge of the ground. Five load tests bring the equivalent factor down to about 1.4 to 1.5 with the recommended values. One borehole keeps it near 2. The allowable-stress habit of using one factor for both cases either wastes pile or takes on risk.
- Installation. Bored-pile bases get the highest factors (1.6 in R4, 2.0 in the UK) because base resistance in a bored pile depends on workmanship and needs large settlement to mobilise.
- Tension. Shaft resistance in tension has its own, higher factor (1.6 in R4 against 1.3 in compression), and the pile's weight becomes a favourable action.
- Settlement. A global factor of 2.5 to 3 traditionally also kept settlement small. The ultimate limit state factors are not meant to do that, so the serviceability check has to be made on its own.
Running both in PileCalc
The axial pile, drilled-shaft and capacity-vs-length tools start in allowable-stress mode, with separate factors of safety on base and shaft resistance. Switching on limit-state design swaps those for a design basis and leaves the resistance method untouched, so you can run the same pile both ways and see which governs. The result lists every factor applied and where it came from. Start with the Eurocode 7 pile design guide, see the factor sets in Design Approaches 1, 2 and 3 for piles, or go straight to the Eurocode 7 pile design page. The resistance side is explained in skin friction vs end bearing.
Common questions
What factor of safety is Eurocode 7 pile design equivalent to?
It depends on the Design Approach, the National Annex, the pile type and how the resistance was obtained. For a driven pile with a permanent to variable load ratio of 2 to 1, designed from one ground profile with the recommended values, the factors multiply to about 2.0 under Design Approach 1 and 2.2 under Design Approach 2. With five or more static load tests the product falls to about 1.4 to 1.5. Under NTC 2018 with one investigated vertical it is about 2.7.
What is the difference between a partial factor and a factor of safety?
A global factor of safety is one number that divides the ultimate resistance to give an allowable load. Partial factors split that margin: some multiply the actions, some divide the ground strength or the resistance, and correlation or model factors cover the uncertainty of the ground investigation and the calculation. The check compares a factored action with a factored resistance.
Can I convert an allowable-stress pile design to Eurocode 7?
Not by multiplying by a constant. The equivalent factor changes with the ratio of permanent to variable load, the split between base and shaft resistance, the number of load tests or ground profiles, and the pile type. Rerun the check with the characteristic actions and the factors of the governing code.
Why does Eurocode 7 reward more ground investigation?
Because the correlation factors fall as the number of profiles or load tests grows. With the recommended values, ξ3 drops from 1.40 for one profile to 1.25 for ten, and ξ1 from 1.40 for one static load test to 1.00 for five. A single global factor of safety cannot make that distinction.
Does PileCalc support both factors of safety and partial factors?
Yes. The axial pile, drilled-shaft and capacity-vs-length tools use factors of safety by default. Switching on limit-state design replaces them with a design basis to EN 1997-1:2004, NTC 2018 or your own partial factors, and the result reports Ed, Rd and the utilisation for each combination.
Sources
Factor values: EN 1997-1:2004 Annex A as reproduced in JRC EUR 26227 (2013); NTC 2018 Tab. 6.2.I, 6.4.II and 6.4.IV; UK National Annex values as reproduced in Raison and Egan (2016); Irish model factor in Orr (2007). The equivalent factors are this page's own arithmetic on those values.
Keep reading
Eurocode 7 pile design: a step-by-step guide (EN 1997-1)
How to design a pile to Eurocode 7: design actions, characteristic resistance from load tests or calculation, Design Approaches, partial factors and a published check.
ReadEurocode 7 pile design worked example (DA1, DA2, DA3)
A driven pile in stiff clay sized under all three Design Approaches, following JRC example A.8.2 step by step, with the same case run in PileCalc.
ReadEurocode 7 Design Approaches 1, 2 and 3 for piles