Pile cap design: a worked example with pile reactions, one-way shear, punching and flexure
Pile cap design step by step: pile reactions from the pile group equation, then one-way shear, punching shear and flexure for a nine-pile cap.
Pile cap design has two halves. First you find how much load each pile gets. Then you check that the concrete can carry those pile reactions back to the column. This guide works one cap all the way through, by hand, with every number: nine piles, a column load, and a moment about each axis.
The example
| Input | Value |
|---|---|
| Piles | Nine, in a 3 by 3 grid at 1.8 m spacing, with 0.45 m square heads |
| Pile embedment | Heads project 0.3 m into the cap |
| Cap | 4.8 m square. First guess 1.0 m thick, final 1.4 m thick |
| Column | 0.9 m square, at the center of the cap |
| Factored loads | 9,000 kN vertical, 2,700 kN·m about each axis |
| Cap weight | 23.56 kN/m³, with a load factor of 1.25 |
| Concrete and steel | 27.6 MPa concrete, 414 MPa reinforcement |
| Bottom mat | 29 mm bars at 150 mm in both directions, 75 mm cover |
The loads are already factored. The checks below are the sectional checks that PileCalc's pile cap tool runs, and the docs page lists the method and the code clauses behind each one.
Step 1: pile reactions from a rigid cap
A pile cap is thick, so it is treated as rigid. Under a centered load it moves straight down, every pile shortens by the same amount, and identical piles share the load equally: 9,000 kN divided by 9 piles is 1,000 kN per pile.
A moment makes the rigid cap tilt. Piles on one side are pushed down farther and piles on the other side are relieved, in proportion to their distance from the center of the group. That gives the pile group equation:
Pi = P / n + My · xi / Σx² + Mx · yi / Σy²
It has the same form as bending stress in a beam, with piles in place of fibers. For this group, six piles sit 1.8 m from each centerline and three sit on it:
- Σx² = 6 × 1.8² = 19.44 m², and the same about the other axis.
- Change per row for one moment: 2,700 × 1.8 / 19.44 = 250 kN.
- With one moment, the rows carry 1,250, 1,000 and 750 kN per pile.
- With both moments, the heaviest corner pile carries 1,000 + 250 + 250 = 1,500 kN, and the opposite corner carries 1,000 − 250 − 250 = 500 kN. The center pile stays at 1,000 kN.
The total load never changed, but one corner pile carries three times what the opposite corner does. This is why corner piles govern. Check the largest reaction against the capacity of a single pile, and check the smallest: if it drops below zero, that pile is in tension, and the pile and its connection both have to be designed for uplift.
Add the weight of the cap
The 1.4 m cap weighs 4.8 × 4.8 × 1.4 × 23.56 = 760 kN. Factored by 1.25 and shared by nine piles, it adds about 106 kN to each one. The reactions used for the cap checks are:
| Pile | Column loads only | With cap weight (1.4 m cap) |
|---|---|---|
| Heaviest corner | 1,500 kN | 1,606 kN |
| Edge piles next to it | 1,250 kN | 1,356 kN |
| Center pile and the two other corners | 1,000 kN | 1,106 kN |
| Edge piles on the light side | 750 kN | 856 kN |
| Lightest corner | 500 kN | 606 kN |
Step 2: one-way shear
One-way shear, or beam shear, is the cap cracking straight across its full width. The critical section sits one effective shear depth, dv, from the face of the column. Every pile outside that section loads it. Piles inside it do not, because their load runs into the column through a compression strut.
For the demand, PileCalc takes the heavier half of the outer row and mirrors it, a conservative estimate that it also uses for flexure. It then takes off the factored weight of the cap strip outside the section, because that weight acts downward against the piles.
First guess: a cap 1.0 m thick
- dv = 0.844 m, so the critical section is 0.45 + 0.844 = 1.29 m from the center of the column.
- The outer row of pile heads runs from 1.575 m to 2.025 m, so the whole row is outside the section.
- The 1.0 m cap is lighter, so the heaviest corner pile carries 1,575 kN and its neighbor 1,325 kN. Mirrored row: 1,575 + 1,325 + 1,575 = 4,476 kN. Less 156 kN of cap weight outside the section: 4,320 kN.
- The concrete resists 3,178 kN.
- 4,320 / 3,178 = 1.36. The cap fails.
Final: a cap 1.4 m thick
- dv = 1.244 m, so the critical section moves out to 0.45 + 1.244 = 1.69 m.
- That cuts through the pile heads. Only (2.025 − 1.694) / 0.45 = 73.6% of each outer pile is outside the section, so only that share of each reaction counts.
- Mirrored row: 1,606 + 1,356 + 1,606 = 4,567 kN. Times 0.736, less 140 kN of cap weight outside the section: 3,219 kN.
- The concrete resists 4,684 kN.
- 3,219 / 4,684 = 0.69. It passes.
Making the cap thicker helped twice. The resistance went up by almost half, and the demand went down by a quarter because the critical section moved out past part of the outer piles. This is the reason pile caps are so thick.
Step 3: punching shear
At the column
In punching shear, or two-way shear, the column pushes a block of concrete down through the cap. The critical perimeter runs around the column, half an effective shear depth from its face.
- With dv = 1.258 m, the perimeter is a square 0.9 + 1.258 = 2.16 m on a side, 8.63 m around.
- Only the center pile is inside it. The other eight add to the demand: 9,950 kN in total, less 1,106 kN in the center pile, less 758 kN of cap weight outside the perimeter: 8,087 kN before rounding.
- The concrete on that perimeter resists 16,989 kN.
- 8,087 / 16,989 = 0.48.
At a corner pile
Turn the cap upside down and each pile can punch up through it on its own. An interior pile has concrete all the way around it. A corner pile does not: its perimeter is cut short by two free edges, and it is also the pile with the biggest reaction. Only the concrete above the pile head resists, so the shear depth is smaller here, 0.91 m.
For the heaviest corner pile the demand is 1,538 kN against a resistance of 3,635 kN, a ratio of 0.42.
Piles breaking out together
Piles that sit close together can also break out as a group, on one shared perimeter. PileCalc's pile punching tool checks every combination. Enter the corner pile and its two neighbors with the reactions from Step 1 (1,606, 1,356 and 1,356 kN) and the 0.91 m shear depth:
| Piles on the perimeter | Demand | Resistance | Ratio |
|---|---|---|---|
| Corner pile alone | 1,606 kN | 3,228 kN | 0.50 |
| Corner pile and one neighbor | 2,962 kN | 4,052 kN | 0.73 |
| Corner pile and both neighbors | 4,318 kN | 4,454 kN | 0.97 |
The three piles together reach 0.97. It still passes, and the tool's result is a conservative bound: it counts each pile's full reaction and takes no credit for the cap weight. It is still the closest check on the whole cap, and it is easy to miss if you only check piles one at a time.
This tool works with round piles. The example uses the same 0.45 m width as the square pile heads, which is on the safe side for a square pile.
Step 4: flexure
Each side of the cap is a cantilever sticking out from the face of the column, loaded from below by the pile reactions. The critical section for bending is at the column face, so the outer piles sit 1.8 − 0.45 = 1.35 m beyond it.
- Mirrored outer row, the conservative estimate used in the FHWA GEC 12 design example: 1,606 + 1,356 + 1,606 = 4,567 kN, on a lever arm of 1.35 m: 6,165 kN·m.
- The cantilever's own factored weight acts the other way and takes off 376 kN·m. Factored moment: 5,789 kN·m.
- The section also has to carry 1.2 times its cracking moment. Mcr = 5,189 kN·m, so 1.2 Mcr = 6,227 kN·m, which governs.
- 29 mm bars at 150 mm give a resistance of 9,563 kN·m in the weaker direction (the upper layer of the bottom mat, which has the smaller effective depth).
- 6,227 / 9,563 = 0.65.
The steel that resists this moment is the bottom mat, and it has to be anchored past the outer piles to work.
Results at a glance
| Check | 1.0 m cap | 1.4 m cap |
|---|---|---|
| Largest pile reaction (with cap weight) | 1,575 kN | 1,606 kN |
| One-way shear | 1.36, fails | 0.69 |
| Punching at the column | 0.85 | 0.48 |
| Punching at the corner pile | 0.82 | 0.42 |
| Flexure | 0.89 | 0.65 |
| Corner pile and both neighbors together | not run | 0.97 |
You can build this cap in PileCalc's pile cap tool from a blank analysis in a couple of minutes: enter the loads, the cap and the column, generate the 3 by 3 grid, and run. Change the thickness from 1.0 m to 1.4 m and run it again to see every ratio move.
Four checks before you trust a pile cap design
- The rigid cap assumption. The pile group equation only holds when the cap is stiff compared with the piles and the piles are all alike. A thin cap, or piles of different lengths, will share the load differently.
- The loads. Check every load combination, include the weight of the cap, and compare the largest and the smallest pile reaction with what a single pile can take, in compression and in tension.
- The method. Sectional checks suit caps of ordinary proportions. For deep caps with piles close to the column, compare with a strut and tie model, as your design code requires.
- The detailing. The bottom bars have to be anchored past the outer piles, and the piles need enough edge distance and embedment.
Common questions
How do you calculate the load on each pile in a pile cap?
For a rigid cap on identical piles, the load in a pile is the vertical load divided by the number of piles, plus each moment times that pile's distance from the center of the group, divided by the sum of the squared distances of all the piles. In the example, 9,000 kN on nine piles with 2,700 kN·m about each axis gives 1,500 kN at one corner and 500 kN at the opposite corner.
Why are pile caps so thick?
One-way shear usually sets the thickness. A thicker cap has more shear resistance, and its critical section sits farther from the column, so fewer piles, or only part of each pile, load it. In the example, going from 1.0 m to 1.4 m took the one-way shear ratio from 1.36 to 0.69.
Where is the critical section for punching shear in a pile cap?
Around the column, half an effective shear depth from its face. Piles outside that perimeter add to the demand. Each pile is also checked punching up through the cap on its own perimeter, which is cut short by any free edge near the pile.
Which pile governs in a pile cap?
Usually a corner pile. With moment about both axes it has the largest reaction, and its punching perimeter is cut short by two free edges. Check it alone and together with its neighbors.
When should a pile cap be designed with a strut and tie model?
When the cap is deep compared with the distance from the column to the piles, the load travels to the piles through compression struts rather than by beam action, and many codes direct you to a strut and tie model instead of sectional checks. Follow the code that governs your project.
Results are from the PileCalc engine for the inputs shown, rounded. This guide is educational and does not replace a design to the code that governs your project.
Keep reading
Drag load and the neutral plane: worked example
How to calculate drag load from negative skin friction: find the neutral plane, sum the friction above it, and run the three design checks. Worked example.
ReadDrilled shaft capacity: alpha and beta methods
Drilled shaft capacity by hand: the alpha method in clay, the beta method in sand, base resistance, and why the base carries so little at working load.
ReadSlope stability and the method of slices: worked example
Slope stability analysis from first principles: factor of safety, the method of slices, Bishop's simplified method and groundwater, with a worked example.
ReadSee it for yourself
Run a laterally loaded pile in your browser — with the deflected shape, moment diagram, and every input explained.