Guides
7 min read· November 27, 2026

Helical pile capacity: individual bearing vs cylindrical shear, with a worked example

How to calculate helical pile capacity by the individual bearing and cylindrical shear methods, why helix spacing decides which governs, and how to set a target installation torque.


A helical pile carries load on steel plates screwed into the ground. There are two standard ways to calculate its capacity, individual bearing and cylindrical shear, and the design value is the lower of the two. This guide works one pile through both methods by hand, shows how helix spacing moves the answer, and finishes with the target installation torque.

The example

InputValue
Soil, 0 to 2.5 mSoft clay, su = 25 kPa
Soil, below 2.5 mStiff clay, su = 100 kPa
Shaft89 mm (3.5 in) round, 6 m long
Helices300 mm at 4.65 m, 250 mm at 5.40 m, 200 mm at 6.00 m
LoadingCompression, factor of safety 2
Torque factor Kt23 per m (7 per ft)

All three plates sit in the stiff clay. Each plate sits three diameters above the next one, measured by the lower plate's diameter. The smallest plate is at the tip, so each plate cuts into soil the one ahead of it has not disturbed.

Method 1: individual bearing

Treat every plate as a small, deep footing. In clay, the bearing pressure under a deep plate is about nine times the undrained shear strength, the same factor used at the tip of an ordinary pile.

Q = Σ 9 · su · A, where A is the area of each plate.

HelixDiameterArea9 · su · A
Top300 mm0.0707 m²63.6 kN
Middle250 mm0.0491 m²44.2 kN
Bottom200 mm0.0314 m²28.3 kN
Total136.1 kN

Method 2: cylindrical shear

If the plates are close together, the soil between them is trapped and moves with the pile as one plug. The failure surface is then a cylinder of soil shearing against soil, plus bearing on the leading plate. In compression the leading plate is the bottom one.

Q = π · D_avg · L · su + 9 · su · A_bottom

  • Cylinder: π × 0.25 m × 1.35 m × 100 kPa = 106.0 kN. The average plate diameter is 0.25 m and the top and bottom plates are 1.35 m apart.
  • Bearing on the bottom plate: 28.3 kN.
  • Total: 134.3 kN.

Which one governs?

The lower one, because the ground fails by whichever mechanism is easier. Here that is cylindrical shear at 134.3 kN, with individual bearing 1.3% higher at 136.1 kN.

Shaft adhesion is neglected in this example, which is a common and conservative choice for a slender shaft.

Why spacing decides it

Keep the same plates and soil and change only the spacing. Individual bearing does not change, because the plates and the clay strength are the same. The cylinder gets longer, so cylindrical shear rises in a straight line.

Spacing (plate diameters)Individual bearingCylindrical shearGoverns
2.0136.1 kN99.0 kNCylindrical shear
2.5136.1 kN116.6 kNCylindrical shear
3.0136.1 kN134.3 kNCylindrical shear, just
3.5136.1 kN152.0 kNIndividual bearing
4.0136.1 kN169.6 kNIndividual bearing

The 3.0 row is the PileCalc run from the video. The other rows are the same hand formula at other spacings, assuming every plate stays in the stiff clay.

For this pile the two methods cross at about 3 diameters. That is the spacing most manufacturers build into their lead sections. Closer than that and the extra plates add little. Wider than that and the lead section is longer than it needs to be. The crossover is not a universal constant. It moves with the plate sizes and the soil, which is why both methods are run every time.

Allowable load and target torque

With a factor of safety of 2, the allowable load is 134.3 / 2 = 67.2 kN, about 15 kip.

Installation torque gives an independent check in the field. Hoyt and Clemence (1989) compared 91 load tests with the torque recorded at the end of installation and found that capacity is roughly proportional to torque:

Q_ult = Kt × T

Turn it around and the design gives the installer a target: T = 134.3 / 23 = 5.84 kN·m, about 4,300 ft·lb, averaged over the last three helix diameters of penetration.

Kt depends mainly on the shaft. Values around 33 per m (10 per ft) are typical for small square shafts and about 23 per m (7 per ft) for a 3.5 in round shaft, and it drops for larger pipes. The correlation has real scatter, so take Kt from the evaluation report for the product you are installing, or from a load test on the site.

What changes in tension

Turn the load around and each plate bears on the soil above it. For the same pile PileCalc gives:

  • Individual bearing: 119.3 kN, which now governs.
  • Cylindrical shear: 164.0 kN.

Individual bearing drops because the shaft passes through the bearing side of each plate, so that ring of area is lost. Cylindrical shear rises because the leading plate is now the largest one, at the top. The governing method has switched, which is a good reason not to assume it.

Two cautions for anchors. The top plate needs enough embedment to keep the failure deep, at least five plate diameters or so. And in sand, uplift formulas on their own can overpredict, so PileCalc requires measured installation torque before it will report a sand uplift capacity.

If the pile comes up short on torque

Suppose the installer's log shows a final average of 5.2 kN·m instead of 5.84. The torque supports 5.2 × 23 = 119.6 kN, less than the 134.3 kN the design assumed. In installed-pile verification mode PileCalc caps the capacity at 119.6 kN and flags the pile as not verified. The usual responses are to go deeper, or to add a helix.

Four checks before you rely on the number

  1. The plates must end up in the layer you designed for. Capacity comes from the soil at the helices, not the soil at the surface.
  2. Check the steel. The shaft, the couplings and the plates have their own limits, and so does the torque the shaft can take during installation.
  3. Check buckling and lateral load separately. In very soft soil a slender shaft can buckle.
  4. Record torque on every pile, and where the consequences are serious, prove the design with a load test.

Try it

The helical pile tool runs both methods, shows them side by side with the bearing on every plate, and returns the target torque. The method, its limits and its references are in the helical pile docs.

This guide is educational. A capacity calculation supports engineering judgment and does not replace it.

Keep reading

Guides
November 27, 2026

Bearing capacity of soil: worked footing example

Bearing capacity of soil from first principles: Terzaghi's three terms, the Nc, Nq and Nγ factors, and a worked 2 m footing with settlement, eccentric load and groundwater.

Read
Guides
November 27, 2026

How to read a pile load-settlement curve

A worked axial pile example read point by point: how skin friction and end bearing share the load as a pile settles, where the curve bends, and how to pick a capacity at a settlement limit.

Read
Guides
November 27, 2026

How to read lateral pile analysis results

A worked p-y example read plot by plot: what the deflection, bending moment, shear and soil reaction profiles of a pile under lateral load tell you, and what to check.

Read

See it for yourself

Run a laterally loaded pile in your browser — with the deflected shape, moment diagram, and every input explained.

Launch the app