Guides
8 min read· November 27, 2026

Bearing capacity of soil: Terzaghi's three terms and a worked footing example

Bearing capacity of soil from first principles: Terzaghi's three terms, the Nc, Nq and Nγ factors, and a worked 2 m footing with settlement, eccentric load and groundwater.


The bearing capacity of soil is the pressure a footing can put on the ground before the soil underneath shears and the footing punches down. This guide explains where the classic equation comes from, then works one square footing in sand from the ultimate pressure through to settlement, eccentric load and groundwater.

How soil fails under a footing

Load a footing on dense sand or stiff clay and three things happen in order. The soil compresses. A wedge of soil directly under the footing gets trapped and moves down with it. That wedge pushes the soil on either side outward along curved slip surfaces, and the ground beside the footing heaves. This is general shear failure, and the pressure that causes it is the ultimate bearing capacity, qult.

In loose sand or soft clay there is no clear peak. The footing keeps sinking with little heave, which is called local or punching shear. Either way, the design question is what resists the movement of that soil.

Terzaghi's three terms

Terzaghi (1943) wrote the resistance as the sum of three parts:

qult = c·Nc + q·Nq + ½·γ·B·Nγ

  • Cohesion, c·Nc. The soil's own shear strength acting along the slip surface.
  • Surcharge, q·Nq. The weight of the soil beside the footing, above its base. It has to be lifted for the failure to happen, so a deeper footing is stronger. q is the effective stress at the base level.
  • Soil weight, ½·γ·B·Nγ. The weight of the soil inside the failure zone. A wider footing mobilizes a deeper, heavier zone, so this term grows with the width B.

Clay loaded quickly leans on the first term. Sand has no cohesion, so it relies on the second and third.

The bearing capacity factors depend on one number

Nc, Nq and Nγ depend only on the friction angle φ, and they are very sensitive to it.

Friction angle φNcNqNγ
0° (undrained clay)5.141.00
30°30.118.422.4
32°35.523.230.2
35°46.133.348.0
40°75.364.2109.4

Five degrees of friction angle nearly doubles Nq. In the worked example below, changing φ from 30° to 32° raises the ultimate pressure by about 30%. The most important input is one you estimate from a site investigation, so know where it came from.

For clay under fast (undrained) loading, φ is taken as zero. Nγ vanishes and the equation reduces to qult = 5.14·su + q for a strip footing: about five times the undrained shear strength plus the surcharge, with no dependence on width.

From Terzaghi to the general equation

Terzaghi assumed a long strip footing and a vertical, centered load. Meyerhof (1963), Hansen (1970) and Vesić (1973) extended the equation by multiplying each term by correction factors:

  • Shape factors, because a square or rectangular footing fails in three dimensions.
  • Depth factors, for the strength of the soil above the base. Many design manuals, including FHWA GEC 6, leave them out unless that soil is well compacted and will stay in place.
  • Inclination factors, for a load that pushes sideways as well as down.
  • Groundwater. Below the water table the soil is buoyant, so its effective unit weight drops. With the water table at the footing base, the soil weight term is roughly halved.
  • Eccentricity. A moment M moves the resultant off center by e = M / V. Meyerhof's method treats the footing as narrower, with an effective width B′ = B − 2e, and only that reduced area carries the load.

Worked example: a 2 m square footing in sand

InputValue
Footing2 m × 2 m, base 1 m below ground
SoilSand, φ = 32°, c = 0, γ = 18 kN/m³, water table deep
Load1,000 kN gross vertical load at the base
TargetFactor of safety of 3 on bearing
Settlement layer0 to 8 m below the base, E = 30,000 kPa

The steps, using the FHWA GEC 6 form of the general equation with Vesić's Nγ and no depth factors:

  1. Cohesion term: c = 0, so it contributes nothing.
  2. Surcharge: q = 18 × 1 = 18 kPa. With Nq = 23.2 and a shape factor of 1 + tan 32° = 1.62, the term is 18 × 23.2 × 1.62 = 678 kPa.
  3. Soil weight: ½ × 18 × 2 × 30.2 × 0.6 (shape factor) = 326 kPa.
  4. Ultimate bearing pressure: 678 + 326 = 1,004 kPa.
  5. Allowable pressure at a factor of safety of 3: 335 kPa.
  6. Applied pressure: 1,000 kN ÷ 4 m² = 250 kPa. Factor of safety = 1,004 ÷ 250 = 4.0. It passes.

You can run the same footing in PileCalc's shallow footing tool in a couple of minutes. It reports a gross ultimate pressure of 1,004 kPa, a bearing factor of safety of 4.02 and a settlement of about 12 mm.

Why twice as wide carries more than four times the load

Make the same footing 4 m wide. The surcharge term stays at 678 kPa, but the soil weight term doubles to 653 kPa because it scales with B. The ultimate pressure rises to about 1,331 kPa, and it acts on four times the area.

2 m footing4 m footing
Ultimate pressure1,004 kPa1,331 kPa
Area4 m²16 m²
Load at failure4,017 kN21,288 kN
Settlement at 250 kPaabout 12 mmabout 25 mm

The failure load goes up 5.3 times for 4 times the area. On clay with φ = 0 there is no width term, so the same change gives exactly 4 times.

Why settlement usually governs on sand

The last row of that table is the catch. At the same 250 kPa, the wide footing settles about twice as much, because a wider footing stresses the soil to a greater depth. Bearing capacity rises with width while settlement gets worse, so for larger footings on sand the allowable pressure is normally set by a settlement limit (often 25 mm), not by the factor of safety on bearing. Check both every time.

Eccentric load, sliding and groundwater

Three changes to the same 2 m footing, applied one after another, show how quickly the margin moves.

CaseEffectBearing factor of safety
Base case, V = 1,000 kNUniform 250 kPa4.02
Add a moment of 200 kN·me = 0.2 m, B′ = 1.6 m, edge pressures 100 and 400 kPa3.0
Add a horizontal force of 100 kNSliding check: 400 kN friction + 29 kN passive, sliding factor of safety 4.33.0
Raise the water table to 2 m below groundUltimate pressure falls to about 852 kPa2.7

The moment alone uses up the whole margin above the target of 3, with the same footing, soil and vertical load. With the water table 1 m below the base the footing no longer meets the target and needs to be wider.

One caution on the horizontal load. FHWA GEC 6 omits load-inclination factors from the bearing check, while AASHTO LRFD includes them. For this case the AASHTO factors would lower the bearing factor of safety from 3.0 to about 2.5, and PileCalc prints that comparison as a warning. Use the lower value where AASHTO governs.

Four checks before you trust a bearing capacity number

  1. The friction angle. Two degrees can change the answer by 30%. Know which test or correlation it came from.
  2. Groundwater. Use the highest water level the site will see over the life of the structure, not the level on the day of drilling.
  3. Settlement. Check it every time. For wide footings it usually governs.
  4. Layers. The equation assumes one uniform soil. A soft layer within one to two footing widths below the base can control the design.

Common questions

What is the difference between ultimate and allowable bearing capacity?

Ultimate bearing capacity is the pressure at which the soil fails in shear. Allowable bearing capacity is the ultimate value divided by a factor of safety, typically 3, and then checked against the settlement limit. The lower of the two controls.

Does a wider footing always have a higher bearing capacity?

On sand, yes: the soil weight term grows with the width, so the ultimate pressure rises. On clay under undrained loading the ultimate pressure does not depend on width. In both cases a wider footing settles more at the same pressure.

How does groundwater affect bearing capacity?

Water makes the soil buoyant, which lowers the effective unit weight in the soil weight term and, if the water is above the base, in the surcharge term too. A water table at the base of a footing on sand roughly halves the soil weight term.

What factor of safety is used for bearing capacity?

Allowable stress design commonly uses 3 on the ultimate bearing pressure, with 2.5 to 3.5 depending on how well the soil is known and the consequence of failure. LRFD codes apply resistance factors instead.

Results are from the PileCalc footing engine (FHWA GEC 6) for the inputs shown, rounded. Settlement is immediate elastic settlement for the stated modulus. This guide is educational and does not replace a site-specific geotechnical design.

Keep reading

Guides
November 27, 2026

Helical pile capacity: individual bearing vs cylindrical shear

How to calculate helical pile capacity by the individual bearing and cylindrical shear methods, why helix spacing decides which governs, and how to set a target installation torque.

Read
Guides
November 27, 2026

How to read a pile load-settlement curve

A worked axial pile example read point by point: how skin friction and end bearing share the load as a pile settles, where the curve bends, and how to pick a capacity at a settlement limit.

Read
Guides
November 27, 2026

How to read lateral pile analysis results

A worked p-y example read plot by plot: what the deflection, bending moment, shear and soil reaction profiles of a pile under lateral load tell you, and what to check.

Read

See it for yourself

Run a laterally loaded pile in your browser — with the deflected shape, moment diagram, and every input explained.

Launch the app